• F-74/E S.I.T.E, Karachi.
  • info@mianoorengineering.com.pk
15KW-75KW

VST DMD SERİES

DMD VST Series compressors are built with frequency invertors. With variable speed compressors, energy savings up to %36 is possible. This means gaining from the overall cost by %25.

MODEL Capacity(m3/dk) Motor Power  HP/kW Compressor Air Outlet Witdh x Length x Height
8 Bar 10 Bar 13 Bar
min. max. min. max. min. max.
DMD 400 VST 1,50 4,20 1,30 3,7 1,10 3,20 40/30 1'' 1195 x 920 x 1590
DMD 500 VST 2,00 6,20 1,90 5,5 1,50 4,30 50 / 37 1 1/4'' 1195 x 920 x 1590
DMD 600 VST 2,50 7,10 2,10 6,2 1,80 5,40 60 / 45 1 1/2'' 1300 x 1020 x 1765
DMD 750 VST 3,35 9,30 2,85 8,2 2,35 7,00 75 / 55 1 1/2'' 1300 x 1020 x 1765
DMD 1000 VST 4,60 13,00 3,90 11 3,30 9,50 100 / 75 2'' 1550 x 1325 x 1800
15kW-75kW

VST EKO Series

MODEL Capacity m3/min Motor Power kW/hp Noise Level dB(A) Connection Diameter Measurements
(mm)
Weight
(kg)
Weight
(kg)
7 Bar 8 Bar 10 Bar 13 Bar Witdh x Length x Height Air Cooled Water Cooled
EKO 15 D VST 1,1 - 2,7 0,9 - 2,6 0,8 - 2,1 0,6 - 1,7 15/20 74 1'' 1195x820x1495 520 520
EKO 18 D VST 1,1 - 3,2 1,1 - 3,1 0,9 - 2,7 0,7 -2,2 18,5/25 74 1'' 1195x820x1495 550 550
EKO 22 D VST 1,4 -3,8 1,3 - 3,6 1,1 -3,1 0,9 -2,6 22/30 74 1'' 1195x820x1495 580 580
EKO 30 CD VST 2,2 - 5,61 2,03 - 5,26 1,80 - 4,75 1,45 - 4,0 30/40 74 1 1/4 1520x1130x1430 800 800
EKO 37 CD VST 2,7 - 6,8 2,47 - 6,33 2,25 - 5,84 1,80- 4,85 37/50 74 1 1/4 1520x1130x1430 880 880
EKO 45 CD VST 3,14 - 7,92 3,01 - 7,61 2,77 - 7,08 2,30 -6,03 45/60 74 1 1/2 1750x1150x1690 1015 1015
EKO 55 CD VST 4,08 - 9,89 3,85 - 9,30 3,36 - 8,65 2,88 - 7,44 55/75 74 1 1/2 2090x1355x1755 1365 1365
EKO 75 CD VST 5,28 - 12,91 5,04 - 12,38 4,38 - 11,13 3,84 - 9,79 75/100 75 2    2270x1060x1600 1440 1440
EKO 75 SCD VST 5,52 - 14,61 5,16 - 13,79 5,16 - 12,27 4,50 -10,32 75/100 75 2    2270x1060x1600 1540 1540
90 KW - 315 KW

VST 

Ekomak New EKO Series Compressors; constantly monitor the air need and adjust the system in order to stabilize the pressure by feedback sensors. This prevent the energy losses of the load/unload condition. Enerjinin %36’sı tasarruf edilir. Energy savings up to %36 is possible which means gaining from the overall cost by %25.

MODEL Capacity m3/min Motor Power  HP/kW Noise Level dB(A) Compressor Air Outlet Witdh x Length x Height
7 Bar 8 Bar 10 Bar 13 Bar
min. max. min. max. min. max. min. max.
EKO  90CD VST 5,10 16,30 5,00 16,30 4,50 14,50 3,70 11,80 125 / 90 76 2'' 2255 x 1060 x 1600
EKO 110CD VST 6,20 19,60 5,80 18,50 5,30 15,90 4,30 13,50 150 / 110  78 2'' 2255 x 1060 x 1600
EKO 132CD VST 7,90 25,30 7,50 23,80 6,60 21,00 5,70 18,10 180 /132 77 DN 80 2875 x 1750 x 2105
EKO 160CD VST 8,90 28,30 8,40 27,50 7,90 25,20 6,80 21,90 220 / 160 78 DN 80 2875 x 1750 x 2105
EKO 200CD VST 10,70 34,20 10,20 33,10 9,50 30,30 8,10 27,00 270 / 200 79 DN100 3625 x 2105 x 2045
EKO 250CD VST 13,10 41,50 12,30 39,30 11,50 37,50 10,00 32,70 340 / 250 80 DN100 3625 x 2105 x 2045
EKO 250CD VST+ 14,50 46,10 13,30 42,30 12,60 39,40 11,30 34,90 340 / 250 77 DN125 4800 x 2150 x 2275